Escape Room Props Put Magnet Sensor in Right Order to Release Lock Control 12 EM Lock for Exit Room Owner

Escape Room Props Put Magnet Sensor in Right Order to Release Lock Control 12 EM Lock for Exit Room Owner
Price: $100.00 - $90.00
(as of Feb 14,2025 15:08:32 UTC – Details)

Buy Now


Product Description

BearHoHo Escape the Room

BearHoHo Escape the Room

Room Escape Magnetic Sensor Props

Room Escape Magnetic Sensor Props

MAGNETIC SENSOR PROPS

Escape Room Magnetic Props — Put magnet sensor in Right Order or at the Same Time to release lock and control 12 EM lock for player exit room

There is one controller connected with 4 magnet sensors. We call it magnet sensor cause it can detect any object which has strong magnetic, for example: strong magnet, magnetic ring, when players put the strong magnetic object in the right sequence or simultaneous, the door will be opened.

User can decorate the strong little magnetic object into anything which fit for your room, and install the sensor under the wooden board, it is easy to operate.

PACKING LIST

PACKING LIST

Controller

Controller

CONTROLLER

DC 12V Power Port
Setting Button
DIP Switch (Modify the playing mode and reset mode)
Speaker
External Audio Output Port
USB Interface (Modify the voice files)
Input Channels
Output Wiring Interface

PACKING LIST

1 x Controller (with Speaker)

4 x Magnetic Sensor

5 x Magnet

1 x 12V Power Adapter

1 x USB Cable

1 x User Manual

Support owner revise the game mode: Simultaneous Version and Sequence Version
Support owner revise the trigger sequence of your own
Support users to change audio content, audio format is MP3, no more than 16M
The quantity of the magnet sensor can be increased, up to 10 sensors

HOW TO CONNECT 12V EM LOCK

HOW TO CONNECT 12V EM LOCK

HOW TO CONNECT 12V ELECTROMAGNETIC LOCK

1. The red wire of the electromagnetic lock should connect to NC port of the controller. The black wire of the electromagnetic lock should be connected to COM port of the controller.

2. The props just support 12V electromagnetic lock, if the voltage exceeds 12V, it will not work properly.

Tips: Props do NOT include electromagnetic locks, please provide your own.

Playing Modes

Playing Modes

HOW TO PLAY

There are 2 kinds of playing modes in these props: Simultaneous mode and Sequence mode, it is easy to switch the playing modes by the settings switch.

Simultaneous Mode

Step 1: There are some magnetic objects, for example 4 magnetic objects. Players have to find all the magnetic objects first.

Step 2: Player need to place the 4 strong magnetic objects close to 4 magnet sensors at one certain point of time, the props will be triggered and the door lock will be opened.

Sequence Mode

Step 1: There are some magnetic objects, for example 4 magnetic objects. Players have to find all the magnetic object first.

Step 2: Player need to place the magnetic object to the magnetic sensor in the correct order, then the props will be triggered and the door lock will be opened.

HOW TO RESET

HOW TO RESET

HOW TO RESET

There are 3 ways to reset the props.

1. Automatically reset mode

Waiting for 1 minute to automatically reset after successful trigger (There will be a buzzing sound when it reset).

2. Real Time reset mode

Sequence mode – After triggering successfully, put the magnetic object to the magnetic sensor in the correct order again to reset.

Simultaneous mode – Take away all the magnetic objects from the magnetic sensor to reset.

3. Manual reset

Restart the controller to reset.

MODIFY THE RESET MODE

MODIFY THE RESET MODE

MODIFY THE RESET MODE

You could modify the reset mode with settings switch (next to the power port). Then restart the controller and the reset mode will take effect.

Automatically reset mode: 3# up

Real Time reset mode: 3# down

MODIFY THE VOICE FILES

MODIFY THE VOICE FILES

MODIFY THE VOICE FILES

1. Insert the USB cable to the controller, and connect the controller to your PC.

2. Open the removable disk shows in the PC, backup all the original files in the controller.

3. Replace the original file with your favorite sound file (no more than 16M), the path and the file name cannot be changed, the audio file format must be in MP3 format.

4. If you want to format the removable disk, please format it to FAT format only. Please do not format it to FAT32, exFAT or NTFS format.

MODIFY THE TRIGGER SEQUENCE IN SEQUENCE MODE

Power off the controller

Power off the controller

STEP 1

Power off the controller and modify the playing mode to sequence mode (1# UP).

Set Button

Set Button

STEP 2

Keep holding the settings button (Next to the power port) and power on the controller until you hear the voice prompt then you can release the button.

Set the trigger sequence

Set the trigger sequence

STEP 3

Listen to the voice prompt and wait for the voice prompt to end.

Put the magnetic object one by one close to the magnetic sensor with order you want to set.

Save the settings

Save the settings

STEP 4

Press the setting button again to save the sequence and re-power the props to test

WHAT'S ESCAPE THE ROOM

WHAT'S ESCAPE THE ROOM

WHAT’S ESCAPE THE ROOM

Escape The Room puts players in a real-life escape game where they must work together in a race against the clock to solve a series of increasingly challenging puzzles.

Teamwork

Designs all foster a natural need for players to share their ideas. Everything from the puzzle design makes it a necessity for players to naturally collaborate and become the spark for a new perspective to tackle the situation.

Puzzles

An escape game wouldn’t be a fun game without a challenge. However, the puzzles should be a test of wits and teamwork.

There are Simultaneous mode and Sequence mode 2 Playing modes, it is easy to switch the playing modes by the settings switch.
Support owner revise the trigger sequence of your own. The password support 1-50 times inductions, If the player want to open the lock, he must do rightly according your preset. With a user manual, it is easy to set the MAGNET PROPS step by step.
It can controll 12V EM lock for escape room game. Connect 12V EM lock, The red wire of the electromagnetic lock should be connected to NC port of the controller. The black wire of the electromagnetic lock should be connected to COM port of the controller.
There are 3 ways to reset, owner can choose the suitable reset method to set.
Support users to change audio content, audio format is MP3, no more than 16M.

Buy Now